Please use this identifier to cite or link to this item: http://nopr.niscpr.res.in/handle/123456789/26980
Title: Performance degradation of an optical Costas loop due to non-ideal response of 90° hybrid
Authors: Sarkar, B C
Hati, (Ms) R
Issue Date: Jan-1999
Publisher: NISCAIR-CSIR, India
Abstract: Effect of non-ideal response of a 90° hybrid in optical Costas loops has been examined. Even a very slight phase deviation ψ, from the ideal hybrid phase shift of 90° leads to increased power penalties and receiver sensitivities. Choice of the optimum power splitting ratio leading to a minimum BER, for a fixed laser linewidth, also increases. The greater the magnitude of the phase deviation, the more the system performance degradation. The nature of these variations does not depend significantly on the number of in-line optical amplifiers.
Page(s): 66-72
ISSN: 0975-1041 (Online); 0019-5596 (Print)
Appears in Collections:IJPAP Vol.37(01) [January 1999]

Files in This Item:
File Description SizeFormat 
IJPAP 37(1) 66-72.pdf1.5 MBAdobe PDFView/Open