Please use this identifier to cite or link to this item: http://nopr.niscair.res.in/handle/123456789/8213
Title: Design, fabrication and measurement of 90° mass-analyzing magnet
Authors: Jain, S K
Malik, Ritesh
Sekar, K
Naik, P A
Hannurkar, P R
Keywords: Mass analyser
Electron cyclotron resonance source
Transport code
Accelerator toolbox
Issue Date: May-2010
Publisher: CSIR
Abstract: The analyzing magnet is an important part of the accelerator system and widely used for analyzing mass, energy and focusing of the charged particles. A 90° mass-analyzing magnet has been designed and developed using 2D-Poisson codes. The analyzing magnet has been tested off-line and results have been found in good agreement with the design parameters. This magnet has a margin of 20 mm extra effective length, and it will be corrected by machining as desired after observing its performance at the electron cyclotron resonance proton source experimental table. Design, fabrication and test results of 90<sup>o</sup> mass-analyzing magnet have been presented.
Description: 315-320
URI: http://hdl.handle.net/123456789/8213
ISSN: 0975-1041 (Online); 0019-5596 (Print)
Appears in Collections:IJPAP Vol.48(05) [May 2010]

Files in This Item:
File Description SizeFormat 
IJPAP 48(5) 315-320.pdf448.76 kBAdobe PDFView/Open