Title: Holdup measurement in a gas-liquid ejector for a sodium chloride-air system
Authors: Raghuram, P T
Das, T R
Keywords: Holdup measurement
Radiological method
Gamma ray attenuation
Non-reactive system
Issue Date: Mar-2006
Publisher: CSIR
IPC CodeF04B47/00
Abstract: Holdup measurements have been carried out experimentally using gamma ray attenuation method in a gas liquid ejector for a sodium chloride-air system. The measured values are compared with the theoretically predicted values based on feed calculations. Holdup as a function of the liquid flowrate and also its distance from the nozzle of the ejector has been reported in this paper. The results obtained for this non-reactive system are also compared with those of air-water system.
Page(s): 144-148
ISSN: 0975-0991 (Online); 0971-457X (Print)
Source:IJCT Vol.13(2) [March 2006]

Files in This Item:

File Description SizeFormat
IJCT 13(2) 144-148.pdf157.5 kBAdobe PDFView/Open
 Current Page Visits: 626 
Recommend this item


Online Submission of Articles |  NISCAIR Website |  National Knowledge Resources Consortium |  Contact us |  Feedback

Disclaimer: NISCAIR assumes no responsibility for the statements and opinions advanced by contributors. The editorial staff in its work of examining papers received for publication is helped, in an honorary capacity, by many distinguished engineers and scientists.

CC License Except where otherwise noted, the Articles on this site are licensed under Creative Commons License: CC Attribution-Noncommercial-No Derivative Works 2.5 India

Copyright © 2015 The Council of Scientific and Industrial Research, New Delhi. All rights reserved.

Powered by DSpace Copyright © 2002-2007 MIT and Hewlett-Packard | Compliant to OAI-PMH V 2.0

Home Page Total Visits: 47992 since 01-Sep-2015  Last updated on 24-Nov-2015Webmaster: