Please use this identifier to cite or link to this item: http://nopr.niscair.res.in/handle/123456789/55661
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSharma, Anjali-
dc.contributor.authorMaksane, Shalini-
dc.contributor.authorDas, Jhuma-
dc.contributor.authorKumar, Sudhir-
dc.contributor.authorBirdi, Amandeep-
dc.contributor.authorTomo, Sojit-
dc.contributor.authorYadav, Dharmveer-
dc.contributor.authorSharma, Praveen-
dc.date.accessioned2020-11-23T06:55:19Z-
dc.date.available2020-11-23T06:55:19Z-
dc.date.issued2020-12-
dc.identifier.issn0975-0959 (Online); 0301-1208 (Print)-
dc.identifier.urihttp://nopr.niscair.res.in/handle/123456789/55661-
dc.description701-706en_US
dc.description.abstractUse of sanitizers in diagnostic centres causes derangement in quality control values of lipase and triglycerides (TG) analytes during COVID-19. Our study provides a practical insight into the type of sanitizers to be used in a laboratory. Performance Verifier (PV) and reagents (lipase and TG) were contaminated with sanitizer and 70% isopropyl alcohol. Groups formed were- PVNet (G1), PV with Sanitizer (G2), PV with 70% Alcohol (G3), Sanitizer contaminated reagent (G4). Controls PV-1 and PV-2 were run. ANOVA and Tukey’s test among groups and between groups were compared. Significant difference in mean PV-1and PV-2 values of TG [PV-1, PV-2 (P <0.0001)] and lipase TG [PV-1 P <0.0001) PV-2 P <0.001] among all tested groups were observed. Between-group analysis showed significantly higher PV-1 and PV-2 values in sanitizer contaminated PV group (P <0.001) compared to Neat PVs (P <0.001), and PVs contaminated with 70% alcohol (P <0.001). sanitizer contaminated PV-1 values were significantly higher when compared to Neat PV-1 (P <0.001)for lipase. It is advised that isopropyl alcohol (70%) should be preferred over glycerol containing sanitizers to reduce pre-analytical errors for lipase and TG estimation.en_US
dc.language.isoen_USen_US
dc.publisherNISCAIR-CSIR, Indiaen_US
dc.rights CC Attribution-Noncommercial-No Derivative Works 2.5 Indiaen_US
dc.sourceIJBB Vol.57(6) [December 2020]en_US
dc.subjectAnalytesen_US
dc.subjectDihydroxyacetoneen_US
dc.subjectHypertriglyceridemiaen_US
dc.subjectQuinoneimineen_US
dc.titleImpact of sanitizers on quality of Lipase and Triglyceride analytes in clinical laboratoryen_US
dc.typeArticleen_US
Appears in Collections:IJBB Vol.57(6) [December 2020]

Files in This Item:
File Description SizeFormat 
IJBB 57(6) 701-706.pdf654.28 kBAdobe PDFView/Open


Items in NOPR are protected by copyright, with all rights reserved, unless otherwise indicated.