Please use this identifier to cite or link to this item: http://nopr.niscair.res.in/handle/123456789/37351
Title: Effect of high hydrostatic pressure on underwater ultrasonic probe heads used for NDT evaluation of offshore structures
Authors: Bindal, V N
Jain, S K
Gupta, Reeta
Chandra, Subhash
Issue Date: Dec-1995
Publisher: NISCAIR-CSIR, India
Abstract: Normal beam NDT probes have been subjected to high hydrostatic pressure, using a pressure generating system developed at NPL. It was noticed that the probe continued to perform well at pressure upto about 4 x 10(6) Pa, even though it was seen that there was a leakage of water from the connector side. The results of measurement of electrical conductance and its frequency response and change of pulse echo sensitivity with increase of pressure have been reported and discussed.
Page(s): 220-222
URI: http://nopr.niscair.res.in/handle/123456789/37351
ISSN: 0975-1033 (Online); 0379-5136 (Print)
Appears in Collections:IJMS Vol.24(4) [December 1995]