Please use this identifier to cite or link to this item:
Title: Influence of internal heat exchanger on performance of window AC retrofitted with R407C
Authors: Vijayan, R
Srinivasan, P S S
Keywords: Air conditioning
Environmental chamber
Internal heat exchanger
Issue Date: Feb-2009
Publisher: CSIR
Abstract: This paper presents experimental performance analysis of a window air conditioner (capacity, 1 TR) with and without an internal heat exchanger (IHE), along with performance comparison of R22 and R407C in the same AC. Use of IHE has increased coefficient of performance (COP) when running on R22 (5.86%) and R407C (6.3%). When retrofitting R22 systems with R407C, COP is found to drop with (6.26%) and without (6.64%) IHE.
Description: 153-156
ISSN: 0022-4456
Appears in Collections:JSIR Vol.68(02) [February 2009]

Files in This Item:
File Description SizeFormat 
JSIR 68(2) 153-156.pdf108.82 kBAdobe PDFView/Open