NISCAIR Online Periodicals Repository

NISCAIR ONLINE PERIODICALS REPOSITORY (NOPR)  >
NISCAIR PUBLICATIONS >
Research Journals >
Indian Journal of Chemical Technology (IJCT) >
IJCT Vol.15 [2008] >
IJCT Vol.15(5) [September 2008] >


Title: Voltammetric trace determination of sub- μg level chlorate in natural waters
Authors: Sharma, P
Songara, S
Keywords: Chlorate determination
Differential pulse polarography
Water samples
Issue Date: Sep-2008
Publisher: CSIR
Abstract: A simple, rapid and sensitive differential pulse polarographic (DPP) method for the determination of low concentration of chlorate in water samples is presented. It is based on the measurement of increased current of titanium (IV) polarographic reduction wave by the addition of chlorate in oxalic acid medium. A linearity between 1.0 μg mL⁻¹ and 41.20 μg mL⁻¹ of chlorate concentration was obtained with a correlation of coefficient of 0.99.
Page(s): 504-506
ISSN: 0971–457X
Source:IJCT Vol.15(5) [September 2008]

Files in This Item:

File Description SizeFormat
IJCT 15(5) 504-506.pdf73.19 kBAdobe PDFView/Open
 Current Page Visits: 562 
Recommend this item

 

National Knowledge Resources Consortium |  NISCAIR Website |  Contact us |  Feedback

Disclaimer: NISCAIR assumes no responsibility for the statements and opinions advanced by contributors. The editorial staff in its work of examining papers received for publication is helped, in an honorary capacity, by many distinguished engineers and scientists.

CC License Except where otherwise noted, the Articles on this site are licensed under Creative Commons License: CC Attribution-Noncommercial-No Derivative Works 2.5 India

Copyright © 2012 The Council of Scientific and Industrial Research, New Delhi. All rights reserved.

Powered by DSpace Copyright © 2002-2007 MIT and Hewlett-Packard | Compliant to OAI-PMH V 2.0

Home Page Total Visits: 624202 since 06-Feb-2009  Last updated on 13-Nov-2014Webmaster: nopr@niscair.res.in