Please use this identifier to cite or link to this item: http://nopr.niscair.res.in/handle/123456789/25178
Title: Analysis of nitrogen ion beam produced in dense plasma focus device using Faraday Cup
Authors: Bhuyan, H
Mohanty, S R
Borthakur, T K
Rawat, R S
Issue Date: Nov-2001
Publisher: NISCAIR-CSIR, India
Abstract: A nanosecond response Faraday Cup was fabricated and employed to characterize pulsed ion beam of a 2.2 kJ Mather type Dense Plasma Focus Device. The Faraday Cup operating in bias ion collector mode was used to determine the energy spectrum and flux of fast nitrogen ion beam along the electrode axis (0°) of the device. It has been possible to register the ion energy up to a lower kinetic energy threshold of ~7 keV which is a value much lower than that obtained in any previous works. The correlation of the ion beam intensity with filling gas pressure is also reported.
Page(s): 698-703
URI: http://hdl.handle.net/123456789/25178
ISSN: 0975-1041 (Online); 0019-5596 (Print)
Appears in Collections:IJPAP Vol.39(11) [November 2001]

Files in This Item:
File Description SizeFormat 
IJPAP 39(11) 698-703.pdf929.71 kBAdobe PDFView/Open


Items in NOPR are protected by copyright, with all rights reserved, unless otherwise indicated.