Title: Improvement in gas stripping capability by installation of turbo molecular pump system in the tenninal of 15 UD pelletron
Authors: Chopra, S
Pawar, N S
Singh, M P
Kumar, Rakesh
Prasad, J
Patel, V P
Pal, Raj
Kumar, B
Ojha, S
Sota, M
Barua, P
Gargari, S
Joshi, R
Kanjilal, D
Datta, S K
Issue Date: Jan-2001
Publisher: NISCAIR-CSIR, India
Abstract: A new re-circulating turbo molecular pump based pumping system has been designed and installed in the high voltage terminal of 15 UD pelletron. The system has been installed and is being used for regular accelerator operation. The system has helped improvements in the vacuum inside accelerator during gas stripper runs and excellent improvements in beam transmission. The present report explains the details of system installation, performance of accelerator and test results of this system with different beams.
Page(s): 84-86
URI: http://hdl.handle.net/123456789/25133
ISSN: 0975-1041 (Online); 0019-5596 (Print)
Appears in Collections:IJPAP Vol.39(01-02) [January-February 2001]