Please use this identifier to cite or link to this item: http://nopr.niscair.res.in/handle/123456789/22085
Title: Performance characteristics of an eccentric venturimeter with elongated throat for flow rate measurement of solid-liquid flows
Authors: Bharani, S
Mishra, R
Singh, S N
Seshadri, V
Issue Date: Jun-1999
Publisher: NISCAIR-CSIR, India
Abstract: The performance characteristics of an eccentric venturimeter with elongated throat for 68 mm NB pipeline having an area ratio of 0.327 for the measurement of flow rates in solid-liquid flow, have been investigated. The modified geometry of the venturimeter is expected to suppress the erosion rate caused by the motion of solid particles. Copper tailings obtained from a processing plant have been used with water to prepare the solid-liquid mixture. Experiments performed over a wide range of flow velocities and solid concentrations show that the value of discharge coefficient of the eccentric venturimeter with elongated throat is slightly higher for slurry flow as compared to the value obtained for clear water flow. It is also seen that the average value of discharge coefficient obtained at different solid concentrations increases marginally with increase in solid concentration. The redistribution of solids at the throat of the venturimeter has also been investigated at different solid concentrations.
Page(s): 119-124
URI: http://hdl.handle.net/123456789/22085
ISSN: 0975-1017 (Online); 0971-4588 (Print)
Appears in Collections:IJEMS Vol.06(3) [June 1999]

Files in This Item:
File Description SizeFormat 
IJEMS 6(3) 119-124.pdf1.41 MBAdobe PDFView/Open


Items in NOPR are protected by copyright, with all rights reserved, unless otherwise indicated.