Title: Development of potassium-selective ion-sensitive field-effect transistor (ISFET) by depositing ionophoric crown ether membrane on the gate dielectric, and its application to the determination of K⁺-ion concentrations in blood serum
Authors: Khanna, V K
Ahmad, S
Jain, Y K
Jayalakshmi, M
Vanaja, S
Madhavendra, S S
Manorama, S V
Kantam, M Lakshmi
Issue Date: Apr-2007
Publisher: CSIR
IPC CodeC12, C25, G01, H01L21/335
Abstract: This paper reports the fabrication and characterization of potassium ISFET (ion-sensitive field-effect transistor) by deposition of a crown ether layer on the gate. This ISFET is referred to as potassium MEMFET (membrane field-effect transistor) or potassium-selective MEMFET device. Calibration of ISFET in standard KCl solutions has shown that the sensitivity of crown ether-ISFET towards potassium (2.3 mV/mg/L) was approximately double that of the nitride-gate ISFET (1 mV/mg/L) in the 100-400 mg/L range. The mechanism of ISFET potassium sensitivity enhancement by the ionophoric crown ether layer on the gate has been explained. Use of the device for potassium concentration measurements in human blood serum has been demonstrated. The distribution of potassium ion concentrations (151-210 mg/L) in a series of human blood serum samples has been determined from the reference value obtained by atomic absorption spectroscopy and the ISFET sensitivity measured with KCl solutions. These diluted samples showed a constant pH ~ 7.0-7.1, confirming the maintenance of pH within close tolerance by the human body; therefore any errors due to pH variation amongst the samples were eliminated. Sensitivity of the ISFET with/without crown ether coating on the gate towards sodium ions (0.34 mV/mg/L) has been found to be comparatively less than that of the crown ether ISFET for potassium, showing that sodium ions in blood serum do not interfere with the measurements.
Page(s): 112-118
ISSN: 0971-4588
Source:IJEMS Vol.14(2) [April 2007]

Files in This Item:

File Description SizeFormat
IJEMS 14(2) 2007 112-118.pdf831.47 kBAdobe PDFView/Open
 Current Page Visits: 945 
Recommend this item

 

National Knowledge Resources Consortium |  NISCAIR Website |  Contact us |  Feedback

Disclaimer: NISCAIR assumes no responsibility for the statements and opinions advanced by contributors. The editorial staff in its work of examining papers received for publication is helped, in an honorary capacity, by many distinguished engineers and scientists.

CC License Except where otherwise noted, the Articles on this site are licensed under Creative Commons License: CC Attribution-Noncommercial-No Derivative Works 2.5 India

Copyright © 2012 The Council of Scientific and Industrial Research, New Delhi. All rights reserved.

Powered by DSpace Copyright © 2002-2007 MIT and Hewlett-Packard | Compliant to OAI-PMH V 2.0

Home Page Total Visits: 638746 since 06-Feb-2009  Last updated on 15-Dec-2014Webmaster: nopr@niscair.res.in