Please use this identifier to cite or link to this item: http://nopr.niscair.res.in/handle/123456789/1374
Full metadata record
DC FieldValueLanguage
dc.contributor.authorHarimi, Mohamed-
dc.contributor.authorSapuan, S M-
dc.contributor.authorAhmad, M M H Megat-
dc.contributor.authorAbas, Fuad-
dc.date.accessioned2008-05-29T08:48:23Z-
dc.date.available2008-05-29T08:48:23Z-
dc.date.issued2008-06-
dc.identifier.issn0022-4456-
dc.identifier.urihttp://hdl.handle.net/123456789/1374-
dc.description440-444en_US
dc.description.abstractThis study presents effect of excess air and fibre-to-shell (F/S) ratio on heat losses. Five heat losses are computed based on ASME standard (heat loss) and STANJAN code (flue gases). Heat loss due to dry flue gas is major heat loss in boiler and has been found statistically affected by the amount of excess air and F/S ratio, whereas other heat losses are somehow negligible, except heat loss due to moisture and hydrogen in fuel, which is mainly related to variation of F/S ratio. Boiler efficiency may reach 85% practically if global optimisation based on excess air and F/S ratios are consideredM with respect to combustion efficiency (low CO) and thermal efficiency (less heat losses).en_US
dc.language.isoen_USen_US
dc.publisherCSIRen_US
dc.sourceJSIR Vol.67(6) [June 2008]en_US
dc.subjectDry flue gasen_US
dc.subjectExcess airen_US
dc.subjectHeat lossesen_US
dc.subjectPalm oil wastesen_US
dc.subjectRatio of fibre-to-shellen_US
dc.titleNumerical study of heat loss from boiler using different ratios of fibre-toshell toshellen_US
dc.typeArticleen_US
Appears in Collections: JSIR Vol.67(06) [June 2008]

Files in This Item:
File Description SizeFormat 
JSIR 67(6) (2008) 440-444.pdf66.44 kBAdobe PDFView/Open


Items in NOPR are protected by copyright, with all rights reserved, unless otherwise indicated.