Title: Design of solar insolation power logging system with ADC error testing and correction
Authors: Hariharan, K
Rambabu, T J
Rajkumar, R K M
Abhaikumar, V
Keywords: ADC error correction
Renewable energy
Solar energy
Solar radiation
Issue Date: Apr-2011
Publisher: NISCAIR-CSIR, India
Abstract: This study presents a low cost solar insolation meter with accurate measurement of inherent non-linear transfer characteristics of ADC. Measured values were found close to accuracy of highly sophisticated instruments (pyranometer and pyrheliometer), which are costlier for large-scale use, low commercial availability and need for a specialized knowledge for handling. Test results over a long duration under varying seasonal conditions were almost identical to those of a calibrated standard pyranometer.
Description: 300-304
URI: http://hdl.handle.net/123456789/11591
ISSN: 0975-1084 (Online); 0022-4456 (Print)